33
IP2251EN
AP - Advanced Parameters
Display Description
Selections
available
TN - Setting of intervention temperature for NIO electronic anti-freeze
system and automatic HS ramps [°C]
This value does not refer to the ambient temperature, but to the internal
control panel temperature.
20
HS - Automatic ramp adjustment
ON - Enabled
OF - Disabled
When enabled (ON), at low ambient temperatures the start time
increases up
to the maximum value and the acceleration time
and diminishes to the
minimum value.
NOTE: for correct operation, the control panel must be exposed to the same am-
bient temperature as the motors. The intervention temperature can be set with
the selection
→ .
TB - Permanent display of the internal control panel temperature [°C]
WO - Setting of pre-flashing time on opening [s]
Adjustment of the lead time for the switch-on of the flashing light, in
relation to the start of the opening operation from a voluntary command.
00 - Minimum
05 - Maximum
00
WC - Setting of pre-flashing time on closing [s]
Adjustment of the lead time for the switch-on of the flashing light, in
relation to the start of the closing operation from a voluntary command.
00 - Minimum
05 - Maximum
00’’
TS - Setting of renewal of automatic closing time after safety device
release [%]
00 - Minimum
99 - Maximum
99
VR - Setting of learning speed [V]
See paragraph 11.2.1
12. Signals visualised on the display
NOTE: depending on the type of automation and control panel, certain visualisations may
not be available.
12.1 Display of automation status
NOTE: the automation status display mode is only visible with Display visualisation mode
set to 02.
Display Description Display Description
Automation closed Automation opening
Automation open Automation closing, from partial opening