OPERATING INSTRUCTIONS | SMART LINE | BOILING PAN
EN | 02-2015 DOC.N
O
: ST09184-02 27
• Press Increase value once and the following
text flashes.
SPD TIME R PAUSE
XXX XX:XX J XX:XX 1
• ConrmbypressingMenuforwards .
The following text flashes:
SPD TIME R PAUSE
XXX XX:XX J XX:XX 1
• PressIncreasevalue to add a longer pause or
press Decrease value to shorten the pause.
• ConrmbypressingMenuforwards .
The figure 1 in the display changes to 2.
SPD TIME R PAUSE
XXX XX:XX J XX:XX 1
The following text flashes again:
ADJ AGITATOR PROGRAM 1
NAME
SPD TIME R PAUSE
XXX XX:XX X XX:XX 2
Repeat the procedure from the beginning to add
the different agitator values that are required. This
can be done three times in total.
The following text appears in the display:
ADJ AGITATOR PROGRAM 1
NAME
SPD TIME R PAUSE
XXX XX:XX X XX:XX 1
In order to select this program: See Preset agitator
program.
14.2.4 Name agitator program
• Press Increase speed to select agitator
program.
• Press Increase value and STOP simultan-
eously for 3 seconds.
The following text appears in the display:
SELECT PROGRAM
NAME
• Press Increase value or Decrease value to
select the suitable letter or number.
• Press Menu forwards to move forwards to
the next character position or press Menu back
to move back to the previous character. (Max
17 characters).
• Repeat until the program name is entered in the
display.
• Press Increase value and STOP simultan-
eously for 3 seconds.
The new agitator program name appears in the
display:
ADJ AGITATOR PROGRAM 1
XXXXXXXXXX
SPD TIME R PAUSE
XXX XX:XX X XX:XX 1