2.2.8 CHANNEL NAMES
Play and record channels can be named (12 characters max.). The name of record
channels will be displayed on the OSD of the video output monitor when a record
train is loaded, displayed on the E/E monitoring outputs and can also be used to
name clips automatically when the Autoname clip parameter is set to “CAM
name”.
The name of the player channel will be displayed on the OSD, but truncated to 4
characters.
2.2.9 GENERAL TIMECODE SETTINGS
From Multicam version 9 onwards, the management of timecodes has been
improved. The users can now choose which type of timecode they want to use as
the reference to work on a given recorder of a server. This is made possible by
the management of two timecode jump tables.
TIMECODE SETTINGS
The timecode jump tables contain records with timecodes of video material
recorded on the server. A new record is created in the table each time a jump in
timecodes is detected on the recorded material.
The records of timecode jumps allow the identification of all the recorded
material. The timecode jump tables are used on all searches for and
manipulations of video material recorded on a server.
The two timecode jump tables are filled with the following data:
The first table is always filled in with the LTC timecode. This is the timecode
defined on or plugged into the server.
The second table is filled in with the timecodes selected by the user. This can
be one of the following timecode type:
o LTC and VITC (default) timecodes in SD
o LTC, HANC LTC (default) or HANC VITC in HD
Note
The timecode jump tables are circular: when the table is full, the latest
entry will overwrite the oldest one.
For more information on the settings related to the timecode jump tables, refer to
the sections below.
For more information on the settings related to the definition and monitoring of
timecode jumps, refer to section on the timecode statuses in the Server
Monitoring section of the XTnano Tech Ref Software manual.

Table of Contents

Other manuals for EVS XT nano

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EVS XT nano and is the answer not in the manual?

EVS XT nano Specifications

General IconGeneral
BrandEVS
ModelXT nano
CategoryServer
LanguageEnglish

Related product manuals