Page #115 background image
Table
4-19
  
Active/Cold
Replacement
Procedure
of
the
PSUBP
(continued)
Work
Order
Task Reference
15 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
*1
This
unit
and
the
XSCFU
cannot
be
replaced
at
the
same
time.
*2
If
the
replaced
PSUBP
was
in
a
SPARC
M12-2S
with
no
PCIe
cards
mounted,
no
diagnosis
is
necessary
(because
diagnosis
was
performed
in
the
previous
step).
Table
4-20
  
Active/Cold
Replacement
Procedure
of
a
PCI
Expansion
Unit
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
from
a
logical
domain
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
4.2.13 Active/Cold
Replacement
Workflow
of
the
PCI
Expansion
Unit
You
can
perform
active/cold
replacement
of
a
PCI
expansion
unit
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Table
4-20
shows
the
workflow
for
active/cold
replacement
of
a
PCI
expansion
unit.
Table
4-20
describes
the
procedure
for
replacing
a
FRU
while
the
power
cords
of
the
PCI
expansion
unit
are
disconnected.
For
replacement
procedures
for
FRUs
while
the
power
cords
of
the
PCI
expansion
unit
are
connected,
see
"7.1.1
Hot
Replacement"
in
the
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual.
Chapter
4
 
FRU
Replacement
Workflows 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals