Page #198 background imageLoading...
Page #198 background image
Table
5-18
  
Inactive/Cold
Addition
Procedure
of
the
SPARC
M12-2S
(continued)
Work
Order
Task Reference
7 Confirming
that
there
is
no
problem
with
the
added
SPARC
M12-2S
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
8 Configuring
memory
mirroring
if
duplicating
memory
"7.6
Configuring
Memory
Mirroring"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide
9 Adding
the
added
SPARC
M12-2S
to
the
PPAR
configuration
list
for
the
physical
partition
that
is
the
incorporation
destination
"7.7
Creating
a
PPAR
Configuration
List"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide
10 Assigning
the
SPARC
M12-2S
(system
board)
to
the
physical
partition
"7.8.1
Assigning
a
Physical
System
Board
(PSB)
to
a
Physical
Partition
(PPAR)"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide
11 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
12 Powering
on
the
physical
partition
of
the
added
SPARC
M12-2S
"10.9.1
Starting
the
System
With
an
XSCF
Command"
13 Assigning
the
resources
of
the
added
SPARC
M12-2S
to
logical
domains
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
*1
Connect
cables
by
following
the
workflow
of
the
addfru
command.
5.5 System-Stopped/Hot
Addition
Workflows
This
section
describes
the
workflows
for
system-stopped/hot
addition
of
FRUs
to
the
SPARC
M12-2/M12-2S.
Before
performing
addition
work,
be
sure
to
check
the
notes
on
maintenance
work
in
the
Fujitsu
SPARC
M12
Product
Notes
of
the
XCP
version
used.
Each
of
the
following
sections
puts
together
the
order
of
work
and
the
tasks
for
each
FRU
into
a
table.
For
details
on
each
task,
see
the
reference
shown
in
the
table.
The
following
FRUs
are
subject
to
system-stopped/hot
addition:
â– 
PCIe
card
â– 
HDD/SSD
â– 
PCI
expansion
unit
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023176

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals