EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #224 background image
Table
6-9
  
Active/Cold
Removal
Procedure
of
the
SPARC
M12-2S
(continued)
Work
Order
Task Reference
6 Releasing
the
logical
domain
assignment
of
the
I/O
resources
of
the
SPARC
M12-2S
to
be
removed
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
7 Releasing
the
I/O
devices
of
the
SPARC
M12-2S
to
be
removed,
from
the
system
"9.4
Enabling
the
Removal
of
Hardware"
8 Releasing
the
assignment,
to
logical
domains,
of
CPU
resources
(*1)
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
9 Releasing
the
assignment,
to
logical
domains,
of
memory
resources
(*1)
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
10 Confirming
that
you
can
release
the
SPARC
M12-2S
to
be
removed
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
11 Releasing
the
SPARC
M12-2S
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
12 Checking
the
operating
condition
of
the
system
after
releasing
the
SPARC
M12-2S
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
13 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
14 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
15 Releasing
the
SPARC
M12-2S
from
the
building
block
configuration
"9.7
Removing
the
SPARC
M12-2S"
16 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
*1
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
6.3 Inactive/Hot
Removal
Workflows
This
section
describes
the
workflows
for
inactive/hot
removal
of
the
FRUs
mounted
in
the
SPARC
M12-2S.
Before
performing
removal
work,
be
sure
to
check
the
notes
on
maintenance
work
in
the
Fujitsu
SPARC
M12
Product
Notes
of
the
XCP
version
used.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023202

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals