Table
5-12
  
Inactive/Hot
Addition
Procedure
of
a
PCI
Expansion
Unit
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Powering
off
the
physical
partition
containing
the
SPARC
M12-2S
to
which
to
add
a
PCI
expansion
unit
"9.5.1
Stopping
a
Specific
Physical
Partition"
3 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
4Removing
the
PCICS
from
the
SPARC
M12-2S
"12.3.1
Enabling
the
Removal
of
a
PCIe
Card"
5Removing
the
PCIe
card
filler
from
the
PCICS
"12.3.2
Removing
a
PCIe
Card
or
PCIe
Card
Filler"
6 Installing
a
link
card
in
the
PCICS
to
install
it
in
the
SPARC
M12-2S
"12.4.1
Installing
a
PCIe
Card
or
PCIe
Card
Filler"
7 Connecting
a
PCI
expansion
unit
to
the
link
card
"5.2
Connecting
Cables
to
the
PCI
Expansion
Unit"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide
8 Installing
a
PCIe
card
in
the
PCI
expansion
unit.
"12.4.1
Installing
a
PCIe
Card
or
PCIe
Card
Filler"
9 Diagnosing
the
SPARC
M12-2S
that
has
undergone
maintenance
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
10 Confirming
that
there
is
no
problem
with
the
added
PCI
expansion
unit
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
11 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
12 Powering
on
the
physical
partition
containing
the
SPARC
M12-2S
that
underwent
maintenance
"10.9.1
Starting
the
System
With
an
XSCF
Command"
13 Assigning
the
I/O
resource
to
a
logical
domain
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
5.4 Inactive/Cold
Addition
Workflows
This
section
describes
the
workflows
for
inactive/cold
addition
of
FRUs
to
the
SPARC
M12-2S
and
inactive/cold
addition
of
the
SPARC
M12-2S.
Before
performing
addition
work,
be
sure
to
check
the
notes
on
maintenance
work
in
Chapter
5
 
FRU
Addition
Workflows 167

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals