Table
6-3
  
Active/Hot
Removal
Procedure
of
a
PCI
Expansion
Unit
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
usage
status
of
the
PCIe
cards
mounted
in
the
PCI
expansion
unit
to
be
removed
"9.2.2
Checking
the
Assignment
Status
of
I/O
Devices"
3 Releasing
the
I/O
resources
assigned
to
the
PCIe
cards
mounted
in
the
PCI
expansion
unit
to
be
removed
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
4 Confirming
that
you
can
release
the
PCI
expansion
unit
to
be
removed
"9.2.2
Checking
the
Assignment
Status
of
I/O
Devices"
5 Releasing
the
link
card
connected
to
the
PCI
expansion
unit
to
be
removed,
from
the
system
"9.4
Enabling
the
Removal
of
Hardware"
6 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
7Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
8 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
9 Releasing
the
PCI
expansion
unit
to
be
removed
and
the
link
card
"11.3
Removing
a
Link
Cable"
in
the
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual
10 Removing
the
PCICS
in
which
the
link
card
is
mounted
from
the
SPARC
M12-2/
M12-2S
"12.3.1
Enabling
the
Removal
of
a
PCIe
Card"
11 Removing
the
link
card
from
the
PCICS "12.3.2
Removing
a
PCIe
Card
or
PCIe
Card
Filler"
12 Installing
a
PCIe
card
filler
in
the
PCICS
from
which
the
link
card
was
removed,
and
installing
the
PCICS
in
the
SPARC
M12-2/M12-2S
"12.4.1
Installing
a
PCIe
Card
or
PCIe
Card
Filler"
13 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
*1
Reassign
I/O
resources
to
logical
domains
as
required.
For
details,
see
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
6.2 Active/Cold
Removal
Workflows
This
section
describes
the
workflows
for
active/cold
removal
of
the
FRUs
mounted
in
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023192

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals