Caution
-
Before
you
handle
any
unit,
be
sure
to
wear
a
wrist
strap
to
ground
any
static
electricity.
If
you
perform
this
procedure
without
a
wrist
strap,
individual
components
or
the
overall
system
may
be
seriously
damaged.
For
details,
see
"1.5
Precautions
on
Static
Electricity."
Note
-
The
crossbar
cables
can
be
removed
only
in
two
cases.
The
first
is
when
the
physical
partition
dynamic
reconfiguration
(PPAR
DR)
function
releases
the
SPARC
M12-2S
from
a
building
block
configuration,
placing
the
server
in
the
cold
state.
The
second
is
when
the
SPARC
M12-2S
in
a
building
block
configuration
is
placed
in
the
cold
state.
19.2 Before
Maintenance
on
the
Crossbar
Cable
When
replacing
crossbar
cables,
perform
one
of
the
maintenance
procedures
listed
below.
 
-
4.4.13
Inactive/Cold
Replacement
Workflow
of
the
Crossbar
Cable
-
4.6.13
System-Stopped/Cold
Replacement
Workflow
of
the
Crossbar
Cable
When
adding
crossbar
cables
(SPARC
M12-2S),
perform
one
of
the
maintenance
procedures
listed
below.
 
-
5.2.6
Active/Cold
Addition
Workflow
of
the
SPARC
M12-2S
-
5.4.6
Inactive/Cold
Addition
Workflow
of
the
SPARC
M12-2S
-
5.6.6
System-Stopped/Cold
Addition
Workflow
of
the
SPARC
M12-2S
When
removing
crossbar
cables
(SPARC
M12-2S),
perform
one
of
the
maintenance
procedures
listed
below.
 
-
6.2.6
Active/Cold
Removal
Workflow
of
the
SPARC
M12-2S
-
6.4.6
Inactive/Cold
Removal
Workflow
of
the
SPARC
M12-2S
-
6.6.6
System-Stopped/Cold
Removal
Workflow
of
the
SPARC
M12-2S
19.3 Removing
the
Crossbar
Cable
This
section
describes
the
procedure
for
removing
the
crossbar
cable.
1.
Confirm
the
crossbar
cable
to
be
replaced.
Log
in
to
the
XSCF
and
execute
the
showstatus
command
or
showlogs
error
command.
Then,
confirm
the
ports
connected
to
the
crossbar
cables
to
be
replaced.
For
details
on
the
commands,
see
"8.2.2
Identifying
a
Fault."
The
underlined
part
in
the
error
example
below
indicates
that
an
error
has
been
Chapter
19
 
Maintaining
the
Crossbar
Cable 491

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals