4.3.1 Alarm overview screen
Description
The alarm overview screen is opened by tapping ALARMS on the navigation toolbar. The
alarm overview screen shows all currently active alarms. To remove an alarm from this
list, the user must clear the alarm condition (for example drain the excess liquid from
the mixer to clear the weight High High Alarm).
The alarm icon is always gray when the alarm overview screen is open, even when active
alarms exist on the system.
Illustration of the alarm overview
screen
The following illustration shows an example of the alarm overview screen.
The following information is shown for each alarm:
Time
Date
Tag name of the unit where the alarm occurred
Short description of the alarm
94 Xcellerex XDM 50-1000, XDUO 100-1000 mixers Operating Instructions 29251615 AD
4 User interface
4.3 Alarm screens
4.3.1 Alarm overview screen