Page #33 background imageLoading...
Page #33 background image
Section 3 Troubleshooting Flowcharts
Diagnostic Repair Manual 29
Problem 2 – Generator Produces Zero Voltage or Residual Voltage (2-12 VAC) (continued)
Problem 3 – Excessive Voltage/Frequency Droop When Load is Applied
Problem 4 – No Battery Charge Output
TEST 15 -
CHECK LOAD
VOLTAGE &
FREQUENCY
TEST 16 - CHECK
LOAD WATTS &
AMPERAGE
TEST 2 - CHECK /
STEPPER MOTOR
CONTROL
GO TO PROBLEM 8
REDUCE LOAD
END TEST
GOOD
GOOD
BAD
OVERLOADED
NOT OVERLOADED
TEST 17 -
CHECK
BATTERY
CHARGE
OUTPUT
TEST 19 -
CHECK
BATTERY
CHARGE
RECTIFIER
TEST 9 - TEST
STATOR
INSULATION
RESISTANCE
TEST PAGE 13
REPAIR
OR
REPLACE
REPAIR
OR REPLACE
REPLACE
FINISHED
GOOD
GOOD
GOOD
BAD
BAD
BAD
BAD