Faults 2G40, 2G40 H
72
HATZ
Operator’s Manual
9 Faults
9.1 Trouble shooting
General troubleshooting notes
If the cases listed below have been worked through but the fault continues to
persist, please contact your nearest Hatz service station.
The engine does not start or does not start immediately, but it can be turned
with the starter.
Possible causes Remedy Chapter
Speed control lever in
stop or idle position.
Set the speed control lever to
the START position.
7.3.2 Setting the
speed control,
page 35
Stop lever in STOP po-
sition.
Set the lever to the "START"
operating position.
7.5.1 Switching
off the engine
(mechanical),
page 40
No fuel at the injection
pump.
Refuel. 7.7 Refueling,
page 46
Actuate the fuel feed pump
(option).
Systematically check the entire fuel supply. If
this does not yield results:
Check the feed line to the
engine.
Check the fuel filter. 8.2.10 Changing
the fuel filter,
page 67
Injection nozzle is not
functional.
Contact HATZ Service.
Insufficient compression:
Wrong tappet clear-
ance.
Check the tappet clearance
and adjust if necessary.
8.2.7 Checking
and setting the
tappet clearance,
page 62
Cylinder and/or pis-
ton ring wear.
Contact HATZ Service.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hatz 2G40 and is the answer not in the manual?

Hatz 2G40 Specifications

General IconGeneral
Displacement462 cm³
Cooling SystemAir-cooled
Compression Ratio20.5:1
Fuel TypeDiesel
Fuel SystemDirect injection
Starting SystemElectric starter
Engine Type1-cylinder 4-stroke diesel engine
Lubrication SystemForced lubrication