The me interval to detect the excepon.
Sensivity
The higher the value is, the more easily the excepon will be detected, and the higher
possibility of misinformaon would be.
Alarm Delay Times
The device uploads the alarm when the alarm reaches the set number of mes.
4.
Check the selected diagnosis type, and the related type will be detected.
5.
Set arming schedule. See
Set Arming Schedule .
6.
Set linkage method. See Linkage Method Sengs .
7.
Click Save.
Note
The funcon is only supported by certain models. The actual display varies with models.
6.6 Set Audio Excepon Detecon
Audio excepon detecon funcon detects the abnormal sound in the scene, such as the sudden
increase/decrease of the sound intensity, and some certain acons can be taken as response.
Steps
1.
Go to Conguraon → Event → Event and Detecon → Audio Excepon Detecon .
2.
Select one or several audio
excepon detecon types.
Audio Loss Detecon
Detect sudden loss of audio track.
Sudden Increase of Sound Intensity Detecon
Detect sudden increase of sound intensity. Sensivity and Sound Intensity Threshold are
congurable.
Note
●
The lower the sensivity is, the more signicant the change should be to trigger the
detecon.
●
The sound intensity threshold refers to the sound intensity reference for the detecon. It is
recommended to set as the average sound intensity in the environment. The louder the
environment sound, the higher the value should be. You can adjust it according to the real
environment.
Sudden Decrease of Sound Intensity Detecon
Detect sudden decrease of sound intensity. Sensivity is congurable.
3.
Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage methods.
4.
Click Save.
Network Camera User Manual
41