Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
9
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshol, and this status keeps NOT
shorter than Filtering Time, it triggers the pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps NOT
shorter than the Filtering Time, it triggers the alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to set link the pre-alarm or alarm with the
connected alarm device.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.
Note
Go toImage VCA Rules Displayto adjust the fonts size and the temperature colour of normal,
alarm and pre-alarm.
3.3.3 Set Expert Mode
Select the temperature measurement rules from Point, Line, or Area and configure parameters,
the device alarms if the alarm rules are met.
Steps
1. Go to Configuration Temperature Measurement Basic Settings, check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration Temperature Measurement Advanced Settings, select Expert.
4. Refer to Set Preset to set a preset.
5. Select and enable the temperature measurement rules. Please refer to Set Thermography Rule
for setting the rule.
6. Optional: Click Area's Temperature Comparison to set the alarm rules and the temperature.
7. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
8. Click Save.
The maximum temperature and thermography rules will be displayed on the live view.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION HM-TD5567T-7/W and is the answer not in the manual?

HIKVISION HM-TD5567T-7/W Specifications

General IconGeneral
BrandHIKVISION
ModelHM-TD5567T-7/W
CategorySecurity Camera
LanguageEnglish

Related product manuals