PAGE - 70 Programming Manual AM_8200
NOTIFIER ITALIA Doc. M-162.1-AM8200-ENG Rev A2 AM8200_manu-prog-ENG
Appendix B : Software Type_ID for MODULES
TABLE‐1
InputmodulesforCONTACTS CBEY/N
MON3
InputModule3TresholdEN54 Y
MON
InputModule2Treshold(NOTEN54compliant) Y
PULL
SameasMON,butlabel“MANUALCallPoint”. Y
NONA
InputModuleNonAlarm Y
STAT
InputModulesameasNONA,signalbothstatusvariation Y
NCMN
InputModuleforN.C.contacts Y
MTRB
InputModuleTamper. N
MACK
InputModuleforremoteACK(pulse). N
MTAC
InputModuleforremoteSILENCE(pulse). N
MRES
InputModuleforremoteRESET(pulse). N
SCON
InputModuleconventionalzone Y
TABLE‐2
OutputModulesSupervisedOutputAdvancedandVDS CBEY/N
CON
OutputModulesupervised Y
CONV
OutputModulesupervisedVDS Y
FORC
OutputModule–Relayoutputcontactsfreevoltage. Y
PWRC
OutputModuleFORCinterruptsmomentarilythepowersupply(usedforreset
conventionaldetectors)
N
GPND
OutputModuleFORCactivatedateachalarm/fault. N
APND
OutputModuleFORCactivatedateachalarm. N
GAC
OutputModuleFORCactivatedateachalarm. N
GAS
OutputModuleCONactivatedateachalarm. N
GASV
SameasGASbutwithcontrolledVDSoutput N
TPND
OutputModuleFORCactivatedateachfault. N
GTC
OutputModuleFORCactivatedateachfault. N
GTS
OutputModuleCONactivatedateachfault. N
GTSV
SameasGTSbutwithcontrolledVDSoutput N
TRS
OutputModuleFORCactivatedateachfault. N
ZDIS
OutputModuleactivatedincaseofexclusionofpointorzone. N
MAINF
OutputModule(notsupervised)activatedforPowerFailure. N
MAINFC
ComeMANIF,supervised N
MAINFV
ComeMANIF,maconuscitasupervisionata(EOLREScompliesVdS) N
REM
OutputModuleconcontattiliberidapotenziale,comandabilesolodasupervisione N
REMC
SameasREMsupervised N
REMV
SameasREM,supervised(EOLREScompliesVdS) N
SND
OutputModulewhichfollowsthestatusofthepanelSounderOutput N
ZFLT
OutputModuleFORCactivatedwhentheassociatedzoneisinfault N
ZFLTC
comeZFLTsupervised N
ZFLTV
comeZFLTsupervisedVdS N
TABLE‐2B
OutputModulesSupervisedOutputAdvancedandNOTVDS CBEY/N
CON
OutputModulesupervisedOutput Y
FORC
OutputModulerelaywithpotential‐freecontacts. Y
PWRC
OutputModuleFORCinterruptsmomentarilythepowersupply N
GPND
OutputModuleFORCactivatedateveryalarm/fault. N
APND
OutputModuleFORCactivatedateveryalarm. N
GAC
OutputModuleFORCactivatedateveryalarm. N
GAS
OutputModuleCONactivatedateveryalarm. N
TPND
OutputModuleFORCactivatedateveryfault.. N
GTC
OutputModuleFORCactivatedateveryfault.. N
GTS
OutputModuleCONactivatedateveryfault.. N
TRS
OutputModuleFORCactivatedateveryfault.. N
ZDIS
OutputModuleactivatedincaseofexclusionofpointorzone. N

Table of Contents

Other manuals for Honeywell NOTIFIER AM-8200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell NOTIFIER AM-8200 and is the answer not in the manual?

Honeywell NOTIFIER AM-8200 Specifications

General IconGeneral
BrandHoneywell
ModelNOTIFIER AM-8200
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals