NAMe
Command :TGTctrl:NAMe<N> <name>
The LASTstate command sets a signal name.
<N> An integer, 0 through 7, specifying signal.
<name> A string of up to 14 characters.
Example OUTPUT XXX;":TGTCTRL:NAME0 ’Reset’"
Query :TGTctrl:NAMe<N>?
The NAMe query returns the name of the specified signal. The default names
are SIGNAL 0 through SIGNAL 7.
Returned Format
[:TGTctrl:NAMe<N>] <name><NL>
Example OUTPUT XXX;":TGTCTRL:NAME0?"
TGTctrl Subsystem
NAMe
14–11