1 N/A N/A
Absent
2 N/A N/A
Absent
3 N/A N/A
Absent
4 AC 650 Normal
The values of the "System Config Redundant-module" and "System Actual Redundant-module"
fields depend on the power redundancy solution. Table 7-1 shows the detailed information
about values of the fields in each power redundancy solution.
Table 7-1 Information displayed during a power redundancy failure
Solution System Config Redundant-module System Actual Redundant-module
1+1 1 0
2+1 1 0
3+1 1 0
1+2 2 1
2+2 2 1
For detailed information about the power-supply policy redundant module-count and display
power-supply commands, refer to Device Management in the System Volume of HP SR6600
Routers User Manual.
Solution
Check the information (such as system temperature, PCB voltage, or insufficient power alarms)
displayed on the serial terminal and the Comware V5 software platform.
If the cause cannot be located and the problem persists, record the above information and
contact your local sales agent.
Troubleshooting the FIP
Symptom 1
Symptom
The RUN LED is off, which indicates the router FIP is powered off or hardware is faulty.
Solution
Check that:
The router is powered on.
The FIP is properly inserted into a FIP slot.
The system power is insufficient if the following information is displayed on the serial terminal
or Comware V5 software platform: