EasyManuals Logo
Home>HP>Server>ML330 - ProLiant - G3

HP ML330 - ProLiant - G3 User Manual

HP ML330 - ProLiant - G3
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
Server Specific Troubleshooting
Table D-4: Is the Internal Health LED Green?
Answer Possible Reasons Possible Solutions
No, it is
amber
A processor or DIMM is in pre-failure
condition.
Use amber failure LEDs to identify:
Missing components
Degraded components
Failed components
Improperly installed components
Contact the authorized service provider
for replacement parts and service.
No, it is
red
A processor, PPM, or fan has failed.
Processor 1 is not installed.
A processor is an unsupported type.
Processors are mismatched (speed
and/or type).
A DIMM has experienced a multibit error.
No valid memory is in the system.
The SCSI cabling or terminator
configuration is incorrect on the SCSI
controller.
An overtemperature condition has
occurred.
Use amber failure LEDs to identify:
Missing components
Degraded components
Failed components
Improperly installed components
Contact the authorized service provider
for replacement parts and service.
Yes If the internal health LED is green, refer to Table D-5.
HP ProLiant ML330 Generation 3 Server Setup and Installation Guide D-7
HP CONFIDENTIAL
Writer: Rob Weaver File Name: k-appd Server Specific Troubleshooting.doc
Codename: Flashback Part Number: 322383-001 Last Saved On: 2/11/03 1:35 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ML330 - ProLiant - G3 and is the answer not in the manual?

HP ML330 - ProLiant - G3 Specifications

General IconGeneral
BrandHP
ModelML330 - ProLiant - G3
CategoryServer
LanguageEnglish