EasyManuals Logo
Home>HP>Software>NonStop Pathway/iTS

HP NonStop Pathway/iTS User Manual

HP NonStop Pathway/iTS
694 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #575 background imageLoading...
Page #575 background image
TCP Error Messages
NonStop Pathway/iTS Management Programming Manual—426749-002
12-5
Error-Message Range 3000 Through 3999
3006: ZPWY-ERR-TCP-BADPUPARAMSIZE
The maximum size of a parameter passed in the USING clause of the CALL statement
did not equal the maximum size of the corresponding parameter given in the procedure
division header of the called program.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. Isolate and correct the problem within the SCREEN COBOL program. For
instructions on how to locate the problem within the program, see Additional
Information for Terminal Errors on page 12-3.
3007: ZPWY-ERR-TCP-NOBASEDISPLAY
A screen manipulation was attempted before the execution of a DISPLAY BASE
statement.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. Isolate and correct the problem within the SCREEN COBOL program. For
instructions on how to locate the problem within the program, see Additional
Information for Terminal Errors on page 12-3 at the beginning of this section.
3008: ZPWY-ERR-TCP-BADDATAREF
An attempt was made to reference data outside the SCREEN COBOL program’s local
data area.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. Isolate and correct the problem within the SCREEN COBOL program. For
instructions on how to locate the problem within the program, see Additional
Information for Terminal Errors on page 12-3 at the beginning of this section.
3009: ZPWY-ERR-TCP-BADSCREENTERM
An attempt was made to execute a SCREEN COBOL program unit compiled for one
type of device on an incompatible device. If the device types are compatible, then a
TCP internal error has occurred.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP NonStop Pathway/iTS and is the answer not in the manual?

HP NonStop Pathway/iTS Specifications

General IconGeneral
BrandHP
ModelNonStop Pathway/iTS
CategorySoftware
LanguageEnglish

Related product manuals