SPI Programming Considerations
NonStop Pathway/iTS Management Programming Manual—426749-002
3-31
Security
Security
The owner of the user ID that starts the PATHMON process can set the ZOWNER and
ZSECURITY fields in ZPWY-DDL-DEF-PATHWAY during the execution of a START
PATHWAY command to restrict the use of a specific group of commands. Commands
included in this restricted group are those that can directly alter the state of an object.
Table 3-9 lists the restricted commands and their object types.
Any user can issue all of the other commands.
Naming Guidelines for Applications
By convention, HP uses names beginning with the letter Z (lowercase z in the C
language) for all definitions and all component fields of structures in its definition files
on NonStop systems. To avoid conflicts with names defined by HP, it is best not to
begin any of your own names with uppercase or lowercase Z.
Table 3-9. Restricted Commands and Objects for Pathway/iTS
To Control…
Use These Restricted (Sensitive)
Commands (ZPWY-CMD- ) and Object Types (ZPWY-OBJ- )…
TCP objects ADD TCP
ALTER TCP
CONTROL TCP
REFRESHCODE TCP
STOP TCP
SWITCH TCP
TERM objects ABORT TERM
ADD TERM
ALTER TERM
DELETE TERM
INSPECT TERM
RESUME TERM
START TERM
STOP TERM
SUSPEND TERM
PROG objects ADD PROG
PROGTERM
ALTER PROG
PROGTERM
DELETE PROG
PROGTERM
Tell Messages ADD TELL
DELETE TELL
START TELL
TELL TELL