TCP Error Messages
NonStop Pathway/iTS Management Programming Manual426749-002
12-51
Error-Message Range 3000 Through 3999
3225: ZPWY-ERR-TCP-INSPECTBADTERM
The file name specified with an Inspect command names a device different from the
one currently used for debugging the SCREEN COBOL program.
For a description of tokens that are present in this event message but are not listed or
described here, see “Event Management,” in Section 6 of the TS/MP Management
Programming Manual.
Token Descriptions
ZSPI-TKN-ERROR
contains ZPWY-ERR-TCP-INSPECTBADTERM.
ZPWY-TKN-REQCOMMAND
contains ZPWY-CMD-INSPECT.
ZPWY-TKN-REQOBJECTTYPE
contains ZPWY-OBJ-TERM.
ZPWY-TKN-REQTERMNAME
contains the name of the TERM object for which the Inspect command was issued.
Effect. The operation fails.
Recovery. Reissue the Inspect command, using a valid file name.
3226: ZPWY-ERR-TCP-PMTCPFNS
The PATHMON process requested a function not supported in this version of the TCP
or LINKMON process.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZPWY-TKN-REQCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-REQOBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-REQTERMNAME token-type ZPWY-TYP-TERMNAME
ZPWY-TKN-ERRCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-ERROBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-TERMNAME token-type ZSPI-TYP-TERMNAME.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.