6
Rack-Mounting or Free-Standing
The unit can be mounted in a 19-inch equipment rack using the mounting kit or it can be free standing. Do
not place objects on top of the unit or stack.
CAUTION:
If installing the switch in a free-standing stack of different size Baseline or Super stack 3 units, the smaller
units must be installed above the larger ones. Do not have a free-standing stack of more than six units.
Using the Mounting Kit
The switch is supplied with two mounting brackets and four screws. These are used for rack mounting the
unit. When mounting the unit, refer to the guidelines given in Positioning the Switch.
The switch is 1U (1.7 inches) high and will fit in a standard 19-inch rack.
CAUTION:
Disconnect all cables from the unit before continuing. Remove the self-adhesive pads from the underside
of unit, if already fitted.
To rack-mount the switch:
1. Place the unit the right way up on a hard, flat surface with the front facing towards you.
2. Locate a mounting bracket over the mounting holes on one side of the unit.
3. Insert the two screws supplied in the mounting kit and fully tighten with a suitable screwdriver, as
shown in Figure 49.
Figure 49 Rack Mounting the Unit
4. Insert the unit into the 19-inch rack and secure with suitable screws (not provided), as shown in Figure
50