EasyManuals Logo

Inovance MD310 T2.2B User Manual

Inovance MD310 T2.2B
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
5 Parameter Table
- 28 -
Para� No� Para� Name Setting Range Unit Default Commission
F0-23 Retentive of digital
setting frequency upon
stop
0: Not retentive
1: Retentive
N�A� 0
F0-24 Motor parameter group
selection
0: Motor parameter group 1
1: Motor parameter group 2
N�A� 0
F0-25 Acceleration/
Deceleration time base
frequency
0: Max� frequency (F0-10)
1: Frequency reference
2: 100
Hz 0
F0-26 Base frequency for UP/
DOWN modication
during running
0: Running frequency
1: Frequency reference
N�A� 0
F0-27 Binding command
source to frequency
source
0000 to 9999 N�A� 0000
Group F1: Motor 1 Parameters
Para� No� Para� Name Setting Range Unit Default Commission
F1-00 Motor type selection 0: Common asynchronous motor
1: Variable frequency asynchronous motor
N�A� 0
F1-01 Rated motor power 0�1 to 30�0 kW Model
dependent
F1-02 Rated motor voltage 1 to 1000 V Model
dependent
F1-03 Rated motor current 0�01 to 655�35 A Model
dependent
F1-04 Rated motor frequency 0�01 to max frequency Hz Model
dependent
F1-05 Rated motor speed 1 to 65535 RPM Model
dependent
F1-06 Stator resistance
(asynchronous motor)
0�001 to 65�535 Model
dependent
F1-07 Rotor resistance 0�001 to 65�535 Model
dependent
F1-08 Leakage inductive
reactance
0�01 to 655�35 mH Model
dependent
F1-09 Mutual inductive
reactance
0�1 to 6553�5 mH Model
dependent
F1-10 No-load current
(asynchronous motor)
0�01 to F1-03 A Model
dependent
F1-37 Auto-tuning selection 0: No auto-tuning
1: Static auto-tuning 1
2: Complete dynamic auto-tuning
3: Static auto-tuning 2
N�A� 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T2.2B and is the answer not in the manual?

Inovance MD310 T2.2B Specifications

General IconGeneral
Rated Power2.2 kW
Control ModeV/F control, Sensorless vector control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus RTU
Humidity5% to 95% (non-condensing)
AltitudeBelow 1000m (derating above 1000m)
Operating Temperature-10°C to +40°C (derating above 40°C)

Related product manuals