5 Parameter Table
- 28 -
Para� No� Para� Name Setting Range Unit Default Commission
F0-23 Retentive of digital
setting frequency upon
stop
0: Not retentive
1: Retentive
N�A� 0
F0-24 Motor parameter group
selection
0: Motor parameter group 1
1: Motor parameter group 2
N�A� 0
F0-25 Acceleration/
Deceleration time base
frequency
0: Max� frequency (F0-10)
1: Frequency reference
2: 100
Hz 0
F0-26 Base frequency for UP/
DOWN modication
during running
0: Running frequency
1: Frequency reference
N�A� 0
F0-27 Binding command
source to frequency
source
0000 to 9999 N�A� 0000
■
Group F1: Motor 1 Parameters
Para� No� Para� Name Setting Range Unit Default Commission
F1-00 Motor type selection 0: Common asynchronous motor
1: Variable frequency asynchronous motor
N�A� 0
F1-01 Rated motor power 0�1 to 30�0 kW Model
dependent
F1-02 Rated motor voltage 1 to 1000 V Model
dependent
F1-03 Rated motor current 0�01 to 655�35 A Model
dependent
F1-04 Rated motor frequency 0�01 to max frequency Hz Model
dependent
F1-05 Rated motor speed 1 to 65535 RPM Model
dependent
F1-06 Stator resistance
(asynchronous motor)
0�001 to 65�535 Ω Model
dependent
F1-07 Rotor resistance 0�001 to 65�535 Ω Model
dependent
F1-08 Leakage inductive
reactance
0�01 to 655�35 mH Model
dependent
F1-09 Mutual inductive
reactance
0�1 to 6553�5 mH Model
dependent
F1-10 No-load current
(asynchronous motor)
0�01 to F1-03 A Model
dependent
F1-37 Auto-tuning selection 0: No auto-tuning
1: Static auto-tuning 1
2: Complete dynamic auto-tuning
3: Static auto-tuning 2
N�A� 0