EasyManuals Logo

Inovance MD310 T2.2B User Manual

Inovance MD310 T2.2B
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
5 Parameter Table
- 35 -
Group F8: Auxiliary Functions
Para� No� Para� Name Setting Range Unit Default Commission
F8-00 JOG running frequency 0�00 to max frequency Hz 2�00
F8-01 JOG acceleration time 0�0 to 6500�0 s 20�0
F8-02 JOG deceleration time 0�0 to 6500�0 s 20�0
F8-03 Acceleration time 2 0�0 to 6500�0 s Model
dependent
F8-04 Deceleration time 2 0�0 to 6500�0 s Model
dependent
F8-05 Acceleration time 3 0�0 to 6500�0 s Model
dependent
F8-06 Deceleration time 3 0�0 to 6500�0 s Model
dependent
F8-07 Acceleration time 4 0�0 to 500�0 s Model
dependent
F8-08 Deceleration time 4 0�0 to 6500�0 s Model
dependent
F8-09 Frequency jump 1 0�00 to max frequency Hz 0�00
F8-10 Frequency jump 2 0�00 to max frequency Hz 0�00
F8-11 Frequency jump amplitude 0�00 to max frequency Hz 0�00
F8-12 Forward/Reverse rotation
dead-zone time
0�0 to 3000�0 s 0�0
F8-13 Reverse control 0: Enabled
1: Disabled
N�A� 0
F8-14 Running mode when set
frequency lower than
frequency lower limit
0: Run at frequency lower limit
1: Stop
2: Run at zero speed
N�A� 0
F8-15 Droop control 0�00 to 10�00 Hz 0�00
F8-16 Accumulative power-on time
threshold
0 to 65000 h 0
F8-17 Accumulative running time
threshold
0 to 65000 h 0
F8-18 Startup protection 0: No
1: Yes
N�A� 0
F8-19 Frequency detection value
(FDT1)
0�00 to max frequency Hz 50�00
F8-20 Frequency detection
hysteresis (FDT1 hysteresis)
0�0 to 100�0 (FDT1 level) % 5�0
F8-21 Detection range of frequency
reached
0�00 to 100 (max frequency) % 0�0
F8-22 Jump frequency during
acceleration/deceleration
0: Disabled
1: Enabled
N�A� 1
F8-25 Frequency switchover point
between acceleration time 1
and acceleration time 2
0�00 to max frequency Hz 0�00
F8-26 Frequency switchover point
between deceleration time 1
and deceleration time 2
0�00 to max frequency Hz 0�00
F8-27 Terminal JOG priority 0: Disabled
1: Enabled
N�A� 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T2.2B and is the answer not in the manual?

Inovance MD310 T2.2B Specifications

General IconGeneral
Rated Power2.2 kW
Control ModeV/F control, Sensorless vector control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus RTU
Humidity5% to 95% (non-condensing)
AltitudeBelow 1000m (derating above 1000m)
Operating Temperature-10°C to +40°C (derating above 40°C)