5 Parameter Table
- 44 -
■
Group FP: Para� No� Management
Para� No� Para� Name Setting Range Unit Default Commission
FP-00 User password 0 to 65535 N�A� 0
FP-01 Parameter initialization 0: No operation
01: Restore factory settings except motor
parameters
02: Clear records
04: Restore user backup parameters
501: Back up current user parameters
10: Initialization of power cable payoff
parameters
20: Initialization of mechanical movement
(vertical, horizontal, arm swing) industry
parameters
21: Initialization of inertia industry (fan)
parameters
22: Initialization of lathe industry
parameters
23: Initialization of quick start/stop industry
(printing machine) parameters
N�A� 0
FP-02 AC drive parameter display
property
00 to 11 N�A� 11
FP-03 Individualized parameter
display property
00 to 11 N�A� 00
FP-04 Parameter modication
property
0: Modiable
1: Not modiable
N�A� 0
■
Group A0: Torque Control
Para� No� Para� Name Setting Range Unit Default Commission
A0-00 Speed/Torque control
selection
0: Speed control
1: Torque control
N�A� 0
A0-01 Torque setting source in
torque control
0 to 7 N�A� 0
A0-03 Torque digital setting in torque
control
-200�0 to 200�0 % 150�0
A0-05 Forward max frequency in
torque control
0�00 to max frequency (F0-10) Hz 50�00
A0-06 Reverse max frequency in
torque control
0�00 to max frequency (F0-10) Hz 50�00
A0-07 Acceleration time in torque
control
0�00 to 650�00 s 0�00
A0-08 Deceleration time in torque
control
0�00 to 650�00 s 0�00