EasyManuals Logo

Inovance MD310 T2.2B User Manual

Inovance MD310 T2.2B
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
5 Parameter Table
- 44 -
Group FP: Para� No� Management
Para� No� Para� Name Setting Range Unit Default Commission
FP-00 User password 0 to 65535 N�A� 0
FP-01 Parameter initialization 0: No operation
01: Restore factory settings except motor
parameters
02: Clear records
04: Restore user backup parameters
501: Back up current user parameters
10: Initialization of power cable payoff
parameters
20: Initialization of mechanical movement
(vertical, horizontal, arm swing) industry
parameters
21: Initialization of inertia industry (fan)
parameters
22: Initialization of lathe industry
parameters
23: Initialization of quick start/stop industry
(printing machine) parameters
N�A� 0
FP-02 AC drive parameter display
property
00 to 11 N�A� 11
FP-03 Individualized parameter
display property
00 to 11 N�A� 00
FP-04 Parameter modication
property
0: Modiable
1: Not modiable
N�A� 0
Group A0: Torque Control
Para� No� Para� Name Setting Range Unit Default Commission
A0-00 Speed/Torque control
selection
0: Speed control
1: Torque control
N�A� 0
A0-01 Torque setting source in
torque control
0 to 7 N�A� 0
A0-03 Torque digital setting in torque
control
-200�0 to 200�0 % 150�0
A0-05 Forward max frequency in
torque control
0�00 to max frequency (F0-10) Hz 50�00
A0-06 Reverse max frequency in
torque control
0�00 to max frequency (F0-10) Hz 50�00
A0-07 Acceleration time in torque
control
0�00 to 650�00 s 0�00
A0-08 Deceleration time in torque
control
0�00 to 650�00 s 0�00

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T2.2B and is the answer not in the manual?

Inovance MD310 T2.2B Specifications

General IconGeneral
Rated Power2.2 kW
Control ModeV/F control, Sensorless vector control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus RTU
Humidity5% to 95% (non-condensing)
AltitudeBelow 1000m (derating above 1000m)
Operating Temperature-10°C to +40°C (derating above 40°C)

Related product manuals