EasyManuals Logo

Inovance MD310 T2.2B User Manual

Inovance MD310 T2.2B
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
5 Parameter Table
- 47 -
Para� No� Para� Name Setting Range Unit Default Commission
A2-53 Torque adjustment proportional
gain
0 to 60000 N�A� 10
A2-54 Torque adjustment integral gain 0 to 60000 N�A� 10
A2-55 Speed loop property 00 to 11 N�A� 00
A2-56 Torque feedforward gain 20 to 100 N�A� 80
A2-59 Max. torque coefcient in eld
weakening area
50 to 200 % 80
A2-60 Regenerative power limit 0�0: Not limited
0�1% to 200�0
% 0�0
A2-61 Motor 2 control mode 0: Sensorless vector control (SVC )
2: Voltage/Frequency (V/F) control
N�A� 2
A2-62 Motor 2 acceleration/deceleration
time
0: Same as motor 1
1: Acceleration/Deceleration time 1
2: Acceleration/Deceleration time 2
3: Acceleration/Deceleration time 3
4: Acceleration/Deceleration time 4
N�A� 0
A2-63 Motor 2 torque boost 0�0: Fixed torque boost,
0�1 to 30
% Model
dependent
A2-65 Motor 2 oscillation suppression
gain
0 to 100 N�A� Model
dependent
Group A5: Control Optimization
Para� No� Para� Name Setting Range Unit Default Commission
A5-00 DPWM switchover frequency
upper limit
0�00 to max output frequency Hz Model
dependent
A5-01 PWM modulation mode 0: Asynchronous modulation
1: Synchronous modulation
N�A� 0
A5-02 Dead zone compensation mode
selection
0: No compensation
1: Compensation
N�A� 1
A5-03 Random PWM depth 0 to 10 N�A� 0
A5-04 Fast current limit 0: Disabled
1: Enabled
N�A� 1
A5-05 Max output voltage coefcient 100 to 110 % 105
A5-06 Undervoltage threshold 100�0 to 600�0 % Model
dependent
A5-07 SVC optimization mode selection 0: Not optimized
1: Optimization mode 1
2: Optimization mode 2
N�A� 1
A5-08 Factory reserved 0�0: Invalid
0�1 to 6�0
kHz 0�0
A5-09 Overvoltage threshold 200�0 to 900�0 V Model
dependent

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T2.2B and is the answer not in the manual?

Inovance MD310 T2.2B Specifications

General IconGeneral
Rated Power2.2 kW
Control ModeV/F control, Sensorless vector control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus RTU
Humidity5% to 95% (non-condensing)
AltitudeBelow 1000m (derating above 1000m)
Operating Temperature-10°C to +40°C (derating above 40°C)

Related product manuals