5 Parameter Table
- 48 -
Group A6: AI Curve Setting
Para� No� Para� Name Setting Range Unit Default Commission
A6-00 AI curve 4 minimum input -10�00 to A6-02 V 0�00
A6-01 Corresponding setting of AI
curve 4 minimum input
-100�0 to 100�0 % 0�0
A6-02 AI curve 4 inexion 1 input A6-00 to A6-04 V 3�00
A6-03 Corresponding setting of AI
curve 4 inexion 1 input
-100�0 to 100�0 % 30�0
A6-04 AI curve 4 inexion 1 input A6-02 to A6-06 V 6�00
A6-05 Corresponding setting of AI
curve 4 inexion 1 input
-100�0 to 100�0 % 60�0
A6-06 AI curve 4 max input A6-06 to 10�00 V 10�00
A6-07 Corresponding setting of AI
curve 4 max input
-100�0 to 100�0 % 100�0
A6-08 AI curve 5 minimum input -10�00 to A6-10 V 0�00
A6-09 Corresponding setting of AI
curve 5 minimum input
-100�0 to 100�0 % 0�0
A6-10 AI curve 5 inexion 1 input A6-08 to A6-12 V 3�00
A6-11 Corresponding setting of AI
curve 5 inexion 1 input
-100�0 to 100�0 % 30�0
A6-12 AI curve 5 inexion 1 input A6-10 to A6-14 V 6�00
A6-13 Corresponding setting of AI
curve 5 inexion 1 input
-100�0 to 100�0 % 60�0
A6-14 AI curve 5 max input A6-14 to 10�00 V 10�00
A6-15 Corresponding setting of AI
curve 5 max input
-100�0 to 100�0 % 100�0
A6-24 Jump point of AI1 input
corresponding setting
-100�0 to 100�0 % 0�0
A6-25 Jump amplitude of AI1 input
corresponding setting
0�0 to 100�0 % 0�5
A6-26 Jump point of AI2 input
corresponding setting
-100�0 to +100�0 % 0�0
A6-27 Jump amplitude of AI2 input
corresponding setting
0�0 to 100�0 % 0�5
A6-28 Jump point of AI3 input
corresponding setting
-100�0 to +100�0 % 0�0
A6-29 Jump amplitude of AI3 input
corresponding setting
0�0 to 100�0 % 0�5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T2.2B and is the answer not in the manual?

Inovance MD310 T2.2B Specifications

General IconGeneral
Rated Power2.2 kW
Control ModeV/F control, Sensorless vector control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus RTU
Humidity5% to 95% (non-condensing)
AltitudeBelow 1000m (derating above 1000m)
Operating Temperature-10°C to +40°C (derating above 40°C)

Related product manuals