56 xGen Installation & Programming Guide
Quick Start Guide
Short form programming sheet for a monitored system
This is not a substitute for reading the manual
1. Hard Default Panel Unplug battery & remove power, turn on power,
Enter 971300 within 10 seconds,
2. Soft Default Panel Login to web console,
shortcut 910.910, wait 12 seconds
3. Go To Program Mode Menu
4. Change Program Code Menu, Users
5. Duress Code
6. System Options System, System and Siren Options,
DEOL, Box Tamper
7. System Timers Siren, Strobe, Phone Fault, AC Fail
8. Program Zones Zones, use presets for type, options, and
assigning Partitions
9. Program Partitions Partitions, Partition 1 name, Force Arm,
Partition Entry/Exit Timers
10. Reporting Partition 1, Partition Reporting,
Account Number and Channel Group
11. Set up Receiver Phone #1 Communicator, Channel 1, Account Code,
Format, Phone/Email,
Event List 1
12. Set up Receiver Phone #2 Communicator, Channel 2, Account Code,
Format, Phone/Email,
Event List 1
13. Communicator Communicator, IP Config
14. Download Access Code Communicator, Remote Access
15. Download Control (Remote Access) Communicator, IP Config
16. Autotest
17. Medical Alarm Sounder “ON”
18. Auto Test Control
19. Exit Program Mode
20. Change Master Code (default 1234)
21. Program User Codes Users
22. Set Date & Time Communicator, IP Config
or manually set in System, System Clock
23. Test Testing, Walk Test, Siren Test,
Communicator Test
24. Train Client/End User
Note: If testing reporting, master code does not send open/closing reports by default (see
Feature 2).