EasyManuals Logo
Home>ITech>Test Equipment>IT8000 Series

ITech IT8000 Series User Manual

ITech IT8000 Series
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
Technical Specification
Parameters IT8018-500-90
Dynamic Frequency
500Hz
Min. rising time
≤1ms
Output parameter
Output voltage
range
380V±10% (Three-phase four-wire)
Output frequency
range
47Hz63Hz
Maximum output
current (rms)
24A
Power factor ≥0.99
Harmonic THDI 3%
Islanding protection Active islanding protection
Setup stability-
30min-30min (%of
Output +Offset
Voltage
≤0.05% + 250mV
Current ≤0.1% + 90mA
Setup stability-
30min-8h (%of
Output +Offset
Voltage
≤0.05% + 250mV
Current ≤0.1% + 90mA
Readback stability-
30min (%of Out-
put +Offset
Voltage
≤0.05% + 250mV
Current ≤0.1% + 90mA
Readback stability-
8h (%of Output
+Offset
Voltage
≤0.05% + 250mV
Current ≤0.1% + 90mA
Efficiency
0.92%
Remote Sense
Compensation
≤25V
Command Re-
sponse Time
20mS
Storage
temperature
-10℃~70
Protective function
OVP, OCP, OPP, OTP and Vsense reversed protection
Communication
interface
Standard: USBCANLANoptional: GPIBRS232
Isolation (output to
ground)
750V
Working
temperature
040
Dimension (mm)
483W*801.61D*151.3H
Weight( net)
40KG
Copyright © Itech Electronic Co., Ltd.
117

Table of Contents

Other manuals for ITech IT8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8000 Series and is the answer not in the manual?

ITech IT8000 Series Specifications

General IconGeneral
BrandITech
ModelIT8000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals