Technical Specification
6.1.3 IT8018-500-90
Parameters IT8018-500-90
Rated value ( 0
-40 )
Input voltage
0500V
Input current
090A
Input power
018000W
Input resistance
05556Ω
Min. operating
voltage
2.97V at 90A
Setup Resolution
Voltage
0.01V
Current 0.001A
Power 0.1W
Resistance 0.1Ω
Read Back
Resolution
Voltage
0.01V
Current 0.001A
Power 0.1W
Resistance 0.1Ω
Setup Accuracy
(within 12 months,
25 ±5) ±(of
Output+Offset)
Voltage
≤0.1% + 500mV
Current ≤0.1% + 90mA
Power ≤1%Pmax
Resistance
≤2%Rmax,010%Rmax;≤5%Rmax,10%
Rmax;
Read Back Accu-
racy (within 12
months, 25 ±5)
±(of Output
+Offset)
Voltage
≤0.1% + 500mV
Current ≤0.1% + 90mA
Power ≤1%FS
Resistance
≤2%Rmax,010%Rmax;≤5%Rmax,10%
Rmax;
Ripple (20Hz
-20MHz)
Voltage ≤500mVpp
Current ≤90mArms
Setup Temperature
Coefficient (of
Output/+Offset)
Voltage
≤0.01% + 50mV
Current ≤0.02% + 18mA
Read Back Temper-
ature Coefficient (
of Output/+Offset)
Voltage
≤0.01% + 50mV
Current ≤0.02% + 18mA
Dynamic
Rising slope
90A/ms
Falling slope
90A/ms
Copyright © Itech Electronic Co., Ltd.
116

Table of Contents

Other manuals for ITech IT8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8000 Series and is the answer not in the manual?

ITech IT8000 Series Specifications

General IconGeneral
BrandITech
ModelIT8000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals