Load Function
Run Edit
3. Press the Left/Right key to select Edit and press [Enter].
4. Set the Cut Off Voltage, Cut Off Capacity and other parameters, and then
press [Enter] to confirm.
After the parameter setting is completed, the interface returns to the Battery
function main interface and displays as follows:
BATTERY TEST
Run Edit
5. Press the Left/Right key to select Run and press [Enter].
The instrument will enter the battery test mode and wait for the battery test
to be triggered.
6. Press the [On/Off].
7. Based on the selected trigger method, perform the trigger operation.
The trigger method of the battery test is consistent with the trigger method
of the List function, that is, the List trigger source is also effective for the
Battery function.
If you want to stop running during the battery test, you can do the following:
Press the composite keys [Shift]+[I-set] (Function) on the front panel to enter
the function menu.
At this point, the interface will prompt whether to stop the running of the Func-
tion, you can press the Left/Right key to select Stop, then the current running
will be stopped, and the Function menu item will be displayed, you can re-enter
the Function menu for editing; if Reset is selected, it means to stop the present
running and return to the main interface to wait for the next trigger operation.
4.3 Protection Function
The series instrument provides the protection functions such as overcurrent,
overpower and undervoltage protection. The corresponding protection parame-
ters can be configured in the Protect menu.
Press [Shift]+[R-set] (Protect) to enter Protect menu interface. The descrip-
tions of protect menu are listed in the table below.
Protect Protection function menu
OCP
Overcurrent protection
Off Turn the OCP function off.
On Turn the OCP function on.
Level OCP limit
Copyright © Itech Electronic Co., Ltd.