EasyManuals Logo
Home>ITech>Test Equipment>IT8512A+

ITech IT8512A+ Programming Guide

ITech IT8512A+
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Input Settings
Copyright © ITECH Electronic Co., Ltd. 22
Chapter5 Input Settings
These commands control the input of the electronic load. The INPut, CURRent,
RESistance and VOLTage commands program the actual input current,
resistance, and voltage.
[SOURce:]INPut <bool>
This command is used to set the input status.
Command Syntax
[SOURce:]INPut <bool>
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Examples
INP 1
Query Syntax
INPut[:STATe]?
Returned Parameters
0 | 1
[SOURce:]INPut?
This command is used to query the input status.
Command Syntax
[SOURce:]INPut?
*RST Value
OFF
Examples
INP?
[SOURce:]INPut:SHORt <bool>
This command is used to set the status of short circuit function.
Command Syntax
[SOURce:]INPut:SHORt <bool>

Table of Contents

Other manuals for ITech IT8512A+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8512A+ and is the answer not in the manual?

ITech IT8512A+ Specifications

General IconGeneral
BrandITech
ModelIT8512A+
CategoryTest Equipment
LanguageEnglish

Related product manuals