EasyManuals Logo
Home>ITech>Test Equipment>IT8512A+

ITech IT8512A+ Programming Guide

ITech IT8512A+
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
OCP Testing Commands
Copyright © ITECH Electronic Co., Ltd. 49
Examples
OCP:IST 3
Query Syntax
OCP:ISTart?
Returned Parameters
<NR2>
OCP:ISTart?
This command is used to query the start current of the OCP test.
Command Syntax
OCP:ISTart?
Parameters
None
Unit
A
OCP:IEND <NRf+>
This command is used to set the OCP cut-off current.
Command Syntax
OCP:IEND <NRf+>
Parameters
MIN~MAX
Unit
A
Examples
OCP:IEND 6
Query Syntax
OCP:IEND?
Returned Parameters
<NR2>
OCP:IEND?
This command is used to query the OCP cut-off current.

Table of Contents

Other manuals for ITech IT8512A+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8512A+ and is the answer not in the manual?

ITech IT8512A+ Specifications

General IconGeneral
BrandITech
ModelIT8512A+
CategoryTest Equipment
LanguageEnglish

Related product manuals