Input Settings
Copyright © ITECH Electronic Co., Ltd. 23
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Examples
INP:SHOR 1
Query Syntax
INPut:SHORt?
Returned Parameters
0 | 1
Related Commands
INP
[SOURce:]INPut:SHORt?
This command is used to query the status of short circuit function.
Command Syntax
[SOURce:]INPut:SHORt?
*RST Value
OFF
Examples
INP:SHOR?
[SOURce:]CURRent:RANGe <NRf+>
This command sets the current range of the electronic load module. When you
program a range value, the load automatically selects the range that
corresponds to the value that you program. If the value falls in a region where
ranges overlap, the load selects the range with the highest resolution.
Command Syntax
[SOURce:]CURRent:RANGe <NRf+>
Parameters
MIN ~MAX | MINimum | MAXimum
Unit
A