Page #34 background imageLoading...
Page #34 background image
Input Settings
Copyright © ITECH Electronic Co., Ltd. 25
Examples
SOUR:VOLT:RANG MIN
Query Syntax
[SOURce:]VOLTage:RANGe?
Returned Parameters
<NR2>
[SOURce:]VOLTage:RANGe?
This command is used to query the voltage range of the electronic load module.
Command Syntax
[SOURce:]VOLTage:RANGe?
Parameters
None
Unit
V
*RST Value
MAXimum(high range)
[SOURce:]VOLTage:RANGe:AUTO[:STATe]
This command is used to set the auto-range state of the voltage meter of the
load module.
Command Syntax
[SOURce:]VOLTage:RANGe:AUTO[:STATe] <bool>
Parameters
0 | 1 | ON | OFF
Returned Parameters
1
Examples
VOLT:RANG:AUTO 1
Query Syntax
[SOURce:]VOLTage:RANGe:AUTO[:STATe]?
Returned Parameters
<NR1>