CALibration Subsystem
Copyright © Itech Electronic Co., Ltd. 110
Command Syntax
CALibrate:VOLTage:METEr:POINt <point>
Parameters
P1 | P2 | P3 | P4
Examples
CAL:VOLT:METEr:POIN P2
Related Commands
CAL:STAT CAL:SAV
CALibrate:VOLTage:METEr[:LEVel]
This command is only used in calibration mode. It enters a calibration voltage
value that you obtain by reading an external meter. You must first select a
calibration level (with CALibrate:VOLTage:POINt) for the value being entered.
These constants are not stored in nonvolatile memory until they are saved with
CALibrate:SAVE.
Command Syntax
CALibrate:VOLTage:METEr[:LEVel] <NRf>
Parameters
<external reading>
Unit
V (volts)
Examples
CAL:CURR 3.2223