SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 69
Returned Parameters
<NR3>
Related Commands
INP:TIM
[SOURce:]REMote:SENSe
This command is used to select the remote measure mode for the load.
Command Syntax
[SOURce:]REMote:SENSe[:STATe] <BOOL>
Parameters
0 | 1 | OFF | ON
*RST Value
0
Examples
REM:SENS 0
Query Syntax
[SOURce:]REMote:SENSe[:STATe]?
Returned Parameters
<CRD>
[SOURce:]FUNCtion
These equivalent commands select the input regulation mode of the electronic
load.
CURRent constant current mode
RESistance constant resistance mode
VOLTage constant voltage mode
POWer constant power mode
Command Syntax
[SOURce:]FUNCtion <function>
Parameters
CURRent | RESistance | VOLTage | POWer