IEEE-488 Command Reference
Copyright © Itech Electronic Co., Ltd. 24
Chapter3 IEEE-488 Command Reference
Common commands begin with an * and consist of three letters (command) or
three letters and a ?(query). They are defined by the IEEE 488.2 standard to
perform common interface functions. Common commands and queries are
categorized under System, Status, or Trigger functions and are listed at the end
of this chapter.
Common Commands
Common commands begin with an * and consist of three letters (command)
IEEE 488.2 standard to perform some common interface functions. The
electronic loads respond to the required common commands that control status
reporting, synchronization, and internal operations. The electronic loads also
respond to optional common commands that control triggers, power-on
conditions, and stored operating parameters.
Common commands and queries are listed alphabetically. If a command has a
corresponding query that simply returns the data or status specified by the
command, then both command and query are included under the explanation
for the command. If a query does not have a corresponding command or is
functionally different from the command, then the query is listed separately. The
description for each common command or query specifies any status registers
affected. Refer to chapter “Programming the Status Registers”, which explains
how to read specific register bits and use the information that they return.
Mnemonic
Meaning
Description
*CLS
*ESE <NRf>
*ESE?
*ESR?
*IDN?
*RDT?
*OPC
*OPC?
*RCL <NRf>
*RST
Clear status
Event enable command
Event enable query
Event status query
Identification query
Frame query
Operation complete
command
Operation complete
query
Recall Command
Reset Command
Clears all event registers and Error Queue.
Program the Standard Event Enable Register.
Read the Standard Event Enable Regsister.
Read the Standard Event Status Regsister and
clear it.
Return the manufacturr, model number, serial
number and firmware revision levels of the unit.
Return the type of electronic frame.
Set the Operation Complete bit in the Standard
Event Status Register after all pending
commands have been executed.
Places an ASCII “1” into the output queue when
all pending selected device operations have been
completed.
Returns the Load th the setup configuration
stored in the specified memory location.
Returned the Load to the *RST default
conditions.

Table of Contents

Other manuals for ITech IT8731

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8731 and is the answer not in the manual?

ITech IT8731 Specifications

General IconGeneral
BrandITech
ModelIT8731
CategoryTest Equipment
LanguageEnglish

Related product manuals