Remote Control
Copyright © Itech Electronic Co., Ltd. 8
Use the :CONDition? query commands in the STATus Subsystem to read the
condition registers.
1.4 Event registers
As Figure shows, each status register set has an event register. An event
register is a latched, read-only register whose bits are set by the corresponding
condition register, once a bit in an event register is set, it remains set (latched)
until the register is cleared by a specific clearing operation. The bits of an event
register are logically ANDed with the bits of the corresponding enable register
and applied to an OR gate. The output of the OR gate is applied to the Status
Byte Register.
Use the *ESR? Common Command to read the Standard Event Register. All
other event registers are read using the :EVENt? query commands in the
STATus Subsystem.
An event register is cleared when it is read. The following operations clear all
event registers:
Cycling power
Sending *CLS
1.5 Enable registers
As Figure shows, each status register set has an enable register. An enable
register is programmed by you and serves as a mask for the corresponding
event register. An event bit is masked when the corresponding bit in the enable
register is cleared (0). When masked, a set bit in an event register cannot set a
bit in the Status Byte Register (1 AND 0 = 0).
To use the Status Byte Register to detect events (i.e., serial poll), you must
unmask the events by setting (1) the appropriate bits of the enable registers. To
program and query the Standard Event Status Register, use the *ESE and
*ESE? Common Commands respectively. All other enable registers are
programmed and queried using the :ENABle and :ENABLe? commands in the
STATus Subsystem.
An enable register is not cleared when it is read. The following operations affect
the enable registers:
Cycling power - Clears all enable registers
:STATus:PREset clears the following enable registers:
Operation Event Enable Register
Questionable Event Enable Register
Channel Summary Event Enable Register
*ESE 0 - Clears the Standard Event Status Enable Register.

Table of Contents

Other manuals for ITech IT8731

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8731 and is the answer not in the manual?

ITech IT8731 Specifications

General IconGeneral
BrandITech
ModelIT8731
CategoryTest Equipment
LanguageEnglish

Related product manuals