SCPI Measurement Command
Copyright © Itech Electronic Co., Ltd. 53
Returned Parameters
<NRf>
FETCh:VOLTage:MIN?
This command is used to read the min voltage of the latest measurement.
MEASure:VOLTage:MIN?
This command initiates and executes a new minimum voltage measurement,
and returns the measured input minimum voltage of the electronic load.
Command Syntax
FETCh:VOLTage:MIN?
MEASure:VOLTage:MIN?
Parameters
None
Returned Parameters
<NRf>
FETCh:CURRent[:DC]?
This command is used to get the latest measured DC current.
MEASure:CURRent[:DC]?
This command initiates and executes a new current measurement, and returns
the measured input current of the electronic load.
Command Syntax
FETCh:CURRent[:DC]?
MEASure:CURRent[:DC]?
Parameters
None
Examples
FETC:CURR?
MEAS:CURR?