Maintenance Guide
1-15
(6) If the P-P value is not 2.0V±0.5V, loosen the screw securing the sensor (screw c for the
X-axis and screw e for the Y-axis shown in the figure below).
X-axis
Y-axis
Clearance between the magnescale and sensor head: 0.25 ± 0.1 mm