Maintenance Guide
1-12
1-4. Replacing the Magnescale
Before replacing the magnescale, leave a new magnescale near the machine for 1 hr.
or longer so that its temperature becomes the same as that of the machine.
(1) Detach the magnescale head from the bracket.
(2) Peel off the old magnescale.
(3) Degrease the magnescale mounting surface and magnescale completely.
It is recommended to use "Mechafine Mate" for the degreasing agent.
1-4-1. Magnescale Affixing Position
x X-axis magnescale affixing procedure
(1) With the X-axis affixing jig (part No. 40046036) made in contact with the front of the
LM-guide and the bottom of the X-axis frame, make the magnescale in contact with the
X-axis affixing jig to affix the magnescale.
Magnescale affixing position (deviation in the horizontal direction):
Specification value
r 0.1 mm
Magnescale affixing position and direction
X-axis frame
LM guide X
Magnescale
X-axis magnescale affixing jig
Affix the magnescale at a distance of 27mm from
the left end of the marking line.
Serial No.