Maintenance Guide
1-1
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[1] X-Y UNIT
1-1. Replacing the Timing Belt and Adjusting the Belt Tension
If a tension of any belt drops below the criteria value, you must adjust it.
For details about the criteria value, see “Readjustment on market” of Specification values on
page 1-4.
1-1-1. Timing Belt XM
To carry out the work efficiently, detach the side cover. Remove the cover fixing screws and slide
the cover toward the rear to detach the side cover.
(1) Remove the SM1051052TN (3 pcs.), SL6051292TN (1 pc.) and SL6061092TN (2 pcs.)
fixing the CB support. (No right side cover is equipped.)
If the belt has been replaced, measure the tension again after
several days have elapsed.
Figure 1-1-1-1