EasyManuals Logo
Home>Jungheinrich>Compact Loader>ERE Series

Jungheinrich ERE Series User Manual

Jungheinrich ERE Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
E 27
1113.GB
7.1 Discharge monitor function
When the discharge monitor function is enabled, lifting is cut out when the discharge
limit is reached (the Stop LED is lit). Travel and lowering are still possible. For wet
batteries the residual capacity is 20%, for maintenance-free batteries it is 40%. The
batteries should be recharged when they reach 30% (for wet batteries) or 50% (for
maintenance-free batteries). The yellow LED lights up as warning indicator.
7.2 Operating hours display
Display range between 0.0 and 99,999.0 hours. This is a backlit display.
Z
For maintenance-free batteries a “T” symbol is shown in the operating hours display
(25).
Errormessages
The operating hours display is also used for indicating errors. The error display starts
with an ”E” for Error and a three-digit error number. If several errors occur
simultaneously they are displayed one after the other. The errors are displayed until
they are rectified. Error messages overwrite the service hour display. Most errors
cause the emergency stop to be activated. Errors remain displayed until the control
circuit is switched off (Code lock).
If no CanDis is present, the error code is displayed by the flashing of the discharge
monitor LED.
Z
The manufacturer’s service department has detailed component descriptions with
error codes.
Display for parameter changes (travel programs)
The LC display (23) is used in conjunction with the operator keypad (CanCode (o))
to display the setting parameters. The parameter number and subindex are displayed
alternating with the parameter.
Display: 0280-2 (max. speed) <-> 0000-8 (value)
Z
Settings of parameter group 0XX (code lock) are not displayed.
Hourmeter
Service hours are counted while the truck is operational and one of the following
controls is applied:
Tiller in travel zone "F"
"Slow travel button"
"Lift" button
"Lower" button
7.3 Power up test
On power up the display shows:
the software version of the display instrument (briefly)
the operating hours
the charge status
E 27
1113.GB
7.1 Discharge monitor function
When the discharge monitor function is enabled, lifting is cut out when the discharge
limit is reached (the Stop LED is lit). Travel and lowering are still possible. For wet
batteries the residual capacity is 20%, for maintenance-free batteries it is 40%. The
batteries should be recharged when they reach 30% (for wet batteries) or 50% (for
maintenance-free batteries). The yellow LED lights up as warning indicator.
7.2 Operating hours display
Display range between 0.0 and 99,999.0 hours. This is a backlit display.
Z
For maintenance-free batteries a “T” symbol is shown in the operating hours display
(25).
Errormessages
The operating hours display is also used for indicating errors. The error display starts
with an ”E” for Error and a three-digit error number. If several errors occur
simultaneously they are displayed one after the other. The errors are displayed until
they are rectified. Error messages overwrite the service hour display. Most errors
cause the emergency stop to be activated. Errors remain displayed until the control
circuit is switched off (Code lock).
If no CanDis is present, the error code is displayed by the flashing of the discharge
monitor LED.
Z
The manufacturer’s service department has detailed component descriptions with
error codes.
Display for parameter changes (travel programs)
The LC display (23) is used in conjunction with the operator keypad (CanCode (o))
to display the setting parameters. The parameter number and subindex are displayed
alternating with the parameter.
Display: 0280-2 (max. speed) <-> 0000-8 (value)
Z
Settings of parameter group 0XX (code lock) are not displayed.
Hourmeter
Service hours are counted while the truck is operational and one of the following
controls is applied:
Tiller in travel zone "F"
"Slow travel button"
"Lift" button
"Lower" button
7.3 Power up test
On power up the display shows:
the software version of the display instrument (briefly)
the operating hours
the charge status

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich ERE Series and is the answer not in the manual?

Jungheinrich ERE Series Specifications

General IconGeneral
BrandJungheinrich
ModelERE Series
CategoryCompact Loader
LanguageEnglish

Related product manuals