EasyManuals Logo
Home>Kioti>Tractor>DK55

Kioti DK55 User Manual

Kioti DK55
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
PERIODIC SERVICE 10-9
069OA14A
1. Remove the air cleaner cover and
element.
2. Clean the element:
1) When dry dust adheres to the
element, blow compressed air from
the inside, turning the element. Pres-
sure of compressed air must be un-
der 686kPa (7 kgf/cm3, 99 psi).
2) When carbon or oil adheres to the
element, soak the element in deter-
gent for 15 minutes then wash it
several times in water, rinse with
clean water and dry it naturally.
After element in fully dried, inspect
inside of the element with a light and
check if it is damaged or not.
3. Replace air cleaner element:
Once yearly or after every sixth clean-
ing, whichever comes first.
(1) Element (3) Evacuator Valve
(2) Cover
EVACUATOR VALVE
Open the evacuator valve once a week
under ordinary conditions - or daily when
used in a dusty place - to get rid of large
particles of dust and dirt.
NOTE
Check to see if the evacuator valve is
blocked with dust.
IMPORTANT
The air cleaner uses a dry ele-
ment, never apply oil.
Do not run the engine with filter
element removed.
Be sure to refit the cover with the
arrow
(on the rear of cover)
upright. If the cover is improp-
erly fitted, evacuator valve will not
function and dust will adhere to
the element.
Do not touch the secondary ele-
ment except in cases where re-
placing is required.
(See “Replacing Air Cleaner Sec-
ondary Element” in Every 1 Year
maintenance.)
CLEANING AIR CLEANER PRIMARY
ELEMENT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kioti DK55 and is the answer not in the manual?

Kioti DK55 Specifications

General IconGeneral
BrandKioti
ModelDK55
CategoryTractor
LanguageEnglish

Related product manuals