16. TROUBLESHOOTING
16.1 WHEN MACHINE RUNS OUT OF FUEL
WARNING
The engine will start, so check carefully that the area around the
engine is safe before cranking the engine.
If the machine has run out of fuel, add fuel and then bleed the
air from the fuel system before starting the engine.
PROCEDURE FOR BLEEDING AIR
1. Loosen air bleeding plug 1.
2. Loosen feed pump knob 2 and move the pump up and down to
draw off fuel until air ceases to come out of air bleeding plug 1.
3. After bleeding the air, tighten air bleeding plug 1, then push in
the knob of feed pump 2 and tighten it.
Machine equipped with electrical governor engine
1. Loosen air bleeding plug 1.
2. Loosen priming pump knob for left 2 and for right 3, and move
pump up and to draw off fuel until air off fuel until air ceases to
come out of air bleeding plug 1.
3. After bleeding the air, tighten air bleeding plug 1, then push in
the knob of priming pump 2, 3 and tighten it.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu Avance Loader WA900-3 and is the answer not in the manual?

Komatsu Avance Loader WA900-3 Specifications

General IconGeneral
BrandKomatsu
ModelAvance Loader WA900-3
CategoryConstruction Equipment
LanguageEnglish

Related product manuals