MAINTENANCE
SERVICE PROCEDURE
LUBRICATE DRIVE SHAFT (5 PLACES)
1.
Using a grease pump, pump in grease through the grease
fittings marked by the arrows.
2. Add grease to the spider portion until grease comes out from
the cap seals (5 places).
3.
After greasing, wipe off any old grease that was pushed out.
Carry out the greasing operation every day when operating in places where the grease flows out easily after
traveling through mud or water.
CHECK DRIVE SHAFT
If there is any problem, such as looseness of the drive shaft
connection, play in the spline or bearing portion, or runout of the
shaft, please contact your Komatsu distributor for repair.
4 - 45