4.9 Service procedure
Maintenance Every 1000 hours service
WA470-6H – VEAM946100 4-75
12. Refill the specified quantity of oil through oil filler (F).
13. After filling with oil, check that the oil is at the specified level.
For details, see "Check transmission oil level, add oil (4-39)".
14. Check that there is no leakage of oil from the transmission
case or oil filter.
Clean transmission case breather
1. Loosen bolt (1) and remove cover (3).
2. Remove the mud and dirt from around the breather (2), then
remove breather (2).
After removing the breather, take steps to prevent dirt or dust
from entering the mount.
3. Soak the breather (2) in washing liquid and wash it.
GK043099
F
G
GK047049
3
1
GK047050
2