6.5 Multi-function lever (with/without auxiliary control lever) Attachments, Options
6-26 WA470-6H – VEAM946100
3. Push the FNR switch on the head of the multi-function lever
to the desired position.
If the directional selector pilot lamp on the machine monitor
flashes, the switch or the lever is in one of the following condi-
tions.
! When the directional selector switch actuation switch is at
the OFF position, if the FNR switch is operated to F (or R):
The pilot lamp flashes, and at the same time, the central
warning lamp lights up and the alarm buzzer sounds.
At the same time, “E00 SHIFTLEVER NEUT“ is displayed on
the character display.
Set the FNR switch to the N position.
! When the engine is started, if the directional selector switch
is at the ON position and the directional lever is at N, and the
FNR switch is operated to F (or R):
The pilot lamp flashes, and at the same time, the central
warning lamp lights up and the alarm buzzer sounds.
! If the directional selector switch is at the ON position and the
FNR switch is operated to F (or R):
The pilot lamp flashes, and at the same time, the central
warning lamp lights up and the alarm buzzer sounds.
At the same time, “E00 SHIFTLEVER NEUT“ is displayed on
the character display.
In this condition, the machine will travel in forward or reverse
according to the operation of the directional lever.
Set the directional lever and the FNR switch on the head of
the multi-function lever to the N position.
GK032329
F
N
R