Safety
16
Pos: 11.6.18 /B A/Sicherheit/Eige nmächtiger Umb au und Ersatzteil herstellung @ 1\mod_1201937 705539_78.d ocx @ 55745 @ 2 @ 1
4.8 Unauthorised Conversion/Modification and Spare Parts Production
Conversions or modifications of the machine are permitted only with prior consultation with the
manufacturer. Original spare parts and accessories authorised by the manufacturer help to
ensure safety. Use of other parts may void liability for resulting damage.
Pos: 11.6.19 /B A/Sicherheit/Unz ulässige Betri ebsweisen @ 11\ mod_12233576 99923_78.doc x @ 145527 @ 2@ 1
4.9 Inadmissible Modes of Operation
The operating safety of the delivered machine is guaranteed only when it is used as intended in
compliance with the introductory section "Intended use" of the operating instructions. The limit
values listed in the data charts should not be exceeded under any circumstances.
Pos: 11.7 /BA/Sich erheit/Arbeite ni m Bereich vonHoc hspannungsleit ungen @ 11\ mod_12233574 68516_78.doc x @ 145505 @ 2 @1
4.10 Working in the vicinity of power transmission lines
1 Always take great care when working under or in the vicinity of power transmission lines.
2 Ensure that when in operation or being transported, the machine cannot exceed a total
height of approx. 4m.
3 If there is any need to travel under overhead lines, the machine operator must request
information on the rated voltage and the minimum height of the overhead lines from the
overhead line operator.
4 Always keep the safety distances according to the table.
Rated voltage
kV
Safe distance from overhead lines
m
To 1 1
Above 1 to 110 2
Above 101 to 220 3
Above 220 to 380 4
Pos: 11.8 /BA/---- ------- ----Seitenumbruch----- ----------- @ 0\mo d_11961753112 26_0.docx @ 41 65 @ @ 1